phrasing fix

master
Ondřej Hruška 7 years ago
parent 91bc53a27a
commit 01770b8666
Signed by: MightyPork
GPG Key ID: 2C5FD5035250423D
  1. 4
      UNIT_FCAP.md

@ -10,9 +10,7 @@
### Direct vs Indirect method ### Direct vs Indirect method
The direct method works well for a wide range of frequencies, from Hz to tens of MHz. For The direct method works well for a wide range of frequencies, from Hz to tens of MHz. For
very high frequencies, a prescaller can be enabled. This method has a best-case very high frequencies, a prescaller can be enabled. This method has a resolution of 1 Hz. It could be increased by extending the measurement time, usually 1 second.
resolution of 1 Hz, which could be increased by extending the measurement time, which
already needs to be long, usually 1 second or more for low frequencies.
The indirect method has a sub-Hz resolution and is much faster than the direct method for The indirect method has a sub-Hz resolution and is much faster than the direct method for
low frequencies. It can be used for signals up to tens of kHz, while the direct method low frequencies. It can be used for signals up to tens of kHz, while the direct method

Loading…
Cancel
Save