# Frequency / Pulse measurement
|
|
|
|
- Frequency measurement
|
|
- Direct method (counting pulses in a time period)
|
|
- Indirect method (measuring a single pulse)
|
|
- PWM measurement - Indirect method also reports duty cycle
|
|
- Single pulse measurement
|
|
- Free-running pulse counter
|
|
|
|
### Direct vs Indirect method
|
|
|
|
The direct method works well for a wide range of frequencies, from Hz to tens of MHz. For
|
|
very high frequencies, a prescaller can be enabled. This method has a best-case
|
|
resolution of 1 Hz, which could be increased by extending the measurement time, which
|
|
already needs to be long, usually 1 second or more for low frequencies.
|
|
|
|
The indirect method has a sub-Hz resolution and is much faster than the direct method for
|
|
low frequencies. It can be used for signals up to tens of kHz, while the direct method
|
|
can handle 20 MHz or more without issues.
|
|
|
|
*NOTE:* The accuracy of all measurements is dependent on the system clock speed.
|
|
To measure the system clock using an external counter, you can output it on a pin using
|
|
the MCO function configured in `SYSTEM.INI`.
|
|
|
|
### Burst vs Continuous
|
|
|
|
Both the direct and indirect methods can operate in a free-running or burst mode.
|
|
|
|
- Burst mode performs one or several measurements (with averaging if using the indirect method).
|
|
- Free-running (continuous) mode performs periodic measurements without averaging.
|
|
The advantage is that the last measurement is always immediately available for read-out, without having to wait for the emasurement.
|
|
|
|
## Commands
|
|
|
|
### STOP (0)
|
|
|
|
Stops all ongoing measurements.
|
|
|
|
### INDIRECT_CONT_START (1)
|
|
|
|
Start a free-running frequency / duty cycle measuring using the indirect method.
|
|
|
|
### INDIRECT_BURST_START (2)
|
|
|
|
Start a burst of indirect measurements.
|
|
Waits for the next rising edge before starting the measurements.
|
|
|
|
*Request:*
|
|
- u16 - number of pulses to average
|
|
|
|
*Response:*
|
|
- u16 - core speed in MHz
|
|
- u16 - number of pulses
|
|
- u64 - sum of all periods (in core ticks)
|
|
- u16 - sum of all on-times (positive interval of the pulse)
|
|
|
|
GEX avoids using float here to reduce code size and avoid floating
|
|
point errors. To get the period, use `period_sec = periods / (mhz * 10e6 * count)`
|
|
|
|
Frequency is `freq = 1 / period`.
|
|
|
|
The average duty cycle is `duty = ontimes / periods`
|
|
|
|
### DIRECT_CONT_START (3)
|
|
|
|
Start repeated measurement using the direct method.
|
|
|
|
*Request:*
|
|
- u16 - measurement time (ms)
|
|
- 0 = no change
|
|
- default 1000, configurable in the unit settings
|
|
- u8 - prescaller (1,2,4,8)
|
|
- 0 = no change
|
|
- default 1, configurable in the unit settings
|
|
|
|
### DIRECT_BURST_START (4)
|
|
|
|
Start a single direct measurement (pulse counting) over
|
|
a given time period. Longer periods can be used for higher precision
|
|
using averaging.
|
|
|
|
*Request:*
|
|
- u16 - measurement time (ms), often 1000 (=1s)
|
|
- u8 - prescaller (1,2,4,8)
|
|
- 0 = no change
|
|
- default 1, configurable in the unit settings
|
|
|
|
*Response:*
|
|
- u8 - prescaller (1,2,4,8)
|
|
- u16 - measurement time (ms)
|
|
- u32 - pulse count
|
|
|
|
Calculate the frequency by `freq = (1000 * count * presc) / time_ms`.
|
|
|
|
### FREECOUNT_START (5)
|
|
|
|
Clear and start the free-running pulse counter.
|
|
|
|
*Request:*
|
|
- u8 - prescaller (1,2,4,8)
|
|
- 0 = no change
|
|
- default 1, configurable in the unit settings
|
|
|
|
### MEASURE_SINGLE_PULSE (6)
|
|
|
|
Measure a single pulse on the input. Waits for a rising edge.
|
|
|
|
*NOTE:* The result may be inaccurate if the input is High when starting the measurement.
|
|
|
|
*Response:*
|
|
- u16 - core speed in MHz
|
|
- u32 - pulse length (core ticks)
|
|
|
|
### FREECOUNT_CLEAR (7)
|
|
|
|
Clear the free-running counter while retrieving the current value.
|
|
Normally no pulses should be missed, but please be aware that this
|
|
operation is not atomic and glitches can occur at high frequencies.
|
|
|
|
*Response:*
|
|
- u32 - last counter value
|
|
|
|
### INDIRECT_CONT_READ (10)
|
|
|
|
Read the latest result from the continuous indirect method measurement
|
|
(measurement of individual pulses).
|
|
|
|
*Response:*
|
|
- u16 - core speed in MHz
|
|
- u32 - period (core ticks)
|
|
- u32 - on-time (positive interval of the pulse)
|
|
|
|
Duty cycle is `duty = ontime / period`.
|
|
Period `period_sec = period / (mhz * 10e6)`.
|
|
Frequency `freq = 1 / period_sec`.
|
|
|
|
### DIRECT_CONT_READ (11)
|
|
|
|
Read the latest result from the continuous direct method measurement (pulse counting).
|
|
|
|
*Response:*
|
|
- u8 - prescaller (1,2,4,8)
|
|
- u16 - measurement time (ms)
|
|
- u32 - pulse count
|
|
|
|
Frequency is `freq = (1000 * presc * count) / time_ms`.
|
|
|
|
### FREECOUNT_READ (12)
|
|
|
|
Read the current value of the free-running pulse counter.
|
|
|
|
*Response:*
|
|
- u32 - counter value
|
|
|
|
### SET_POLARITY (20)
|
|
|
|
Set the measured pulse polarity.
|
|
|
|
*NOTE:* This is normally configured in the unit settings.
|
|
Changes done through this method are temporary, not persisted to flash. The same
|
|
applies to the other SET_* commands.
|
|
|
|
*Request:*
|
|
- u8 - active level (0,1)
|
|
|
|
### SET_DIR_PRESC (21)
|
|
|
|
Set prescaller for the direct mode measurement.
|
|
|
|
*NOTE:* This does not take effect until the direct measurement is restarted. (TODO: fix?)
|
|
|
|
*Request:*
|
|
- u8 - prescaller (1,2,4,8)
|
|
|
|
### SET_INPUT_FILTER (22)
|
|
|
|
Set input filtering (a hardware feature designed to ignore short glitches)
|
|
|
|
*Request:*
|
|
- u8 - digital filtering factor (0-15, 0=off)
|
|
|
|
### SET_DIR_MSEC (23)
|
|
|
|
Set direct measurement period.
|
|
|
|
*NOTE:* This does not take effect until the direct measurement is restarted. (TODO: fix?)
|
|
|
|
*Request:*
|
|
- u16 - period in milliseconds
|
|
|
|
### RESTORE_DEFAULTS (30)
|
|
|
|
Stop any measurement and restore all the run-time configurable settings to their default
|
|
values (as configured in the unit settings).
|
|
|