# ADC - analog capture |
||||
|
||||
The ADC unit supports instantaneous readout, exponential averaging and isochronous |
||||
sampling of up to 16 channels (+ two channels dedicated to a bandgap reference and the |
||||
internal temperature sensor). The voltage reference may be used to compensate for supply |
||||
voltage variations and achieve higher accuracy. |
||||
|
||||
The ADC unit has been tested to work up to 75 kSps with 1 channel on the 48 MHz |
||||
STM32F072, higher frequencies made the system unstable. This should be possible to fix |
||||
in a later firmware update. When sampling multiple channels, the maximal frequency |
||||
drops as more data needs to be sent through the communication port. |
||||
|
||||
This unit works in a similar fashion to the frequency capture unit, having multiple |
||||
mutually exclusive opmodes. |
||||
|
||||
All modes use periodic sampling; the frequency can be pre-comnfigured or set using |
||||
a command. |
||||
|
||||
- direct measurement |
||||
- immediate read-out of the latest captured sample |
||||
- averaging available for lower frequencies, f < 20 kHz |
||||
- isochronous sampling |
||||
- a unlimited stream of samples (use e.g. for visualisation) |
||||
- block capture of a fixed length |
||||
- level-trigger started capture with pre-trigger capture (like oscilloscope) |
||||
|
||||
Please note that the opmodes are mutually exclusive, e.g. it's not possible |
||||
to read a averaged sample while streaming - the command will return a BUSY error. |
||||
|
||||
When a stream / block / trigger capture finishes, the unit returns to periodic sampling and direct read-out is available. This is also available when armed for trigger; trigger is implemented by checking the value of those direct samples. |
||||
|
||||
Channels must be configured in the unit settings, this is to claim the pins. They can be enabled/disabled using a command later. |
||||
|
||||
## Commands |
||||
|
||||
### READ_RAW (0) |
||||
Get the last raw sample of enabled channels. |
||||
|
||||
*Response:* |
||||
- u16[] - values for enabled channels, ascending order |
||||
|
||||
### READ_SMOOTHED (1) |
||||
Read the averaged values of enabled channels. |
||||
This function is not available for high sample rates on the STM32F072 due to the soft |
||||
float overhead. |
||||
|
||||
*Response:* |
||||
- float32[] - values for enabled channels, ascending order |
||||
|
||||
### GET_ENABLED_CHANNELS (10) |
||||
Get numbers of all enabled channels. |
||||
|
||||
*Response:* |
||||
- u8[] - numbers of all enabled channels, ascending order |
||||
|
||||
### GET_SAMPLE_RATE (11) |
||||
Get the current sample rate in Hz |
||||
|
||||
*Response:* |
||||
- u32 - sample rate |
||||
|
||||
### SETUP_TRIGGER (20) |
||||
Configure the trigger level and other parameters. |
||||
|
||||
*Request:* |
||||
- u8 - source channel number, 0-based. Must be enabled. |
||||
- u16 - triggering level (0-4095) |
||||
- u8 - triggering edge (1-falling, 2-rising, 3-any) |
||||
- u32 - pre-trigger capture length (samples) |
||||
- u32 - post-trigger capture length (samples) |
||||
- u16 - hold-off time (milliseconds) |
||||
- u8 - auto re-arm (0,1) after hold-off |
||||
|
||||
The trigger is not armed, only configured. Use the `ARM` command to arm. |
||||
This is so the user can manually re-arm without sending the configuration again. |
||||
|
||||
### ARM (21) |
||||
Arm the configured trigger. If already armed, do nothing. |
||||
|
||||
*Request:* |
||||
- u8 - auto re-arm (0,1) after hold-off. |
||||
- 0xFF (255) = no change |
||||
|
||||
### DISARM (22) |
||||
Dis-arm the trigger. |
||||
|
||||
### ABORT (23) |
||||
Abort any ongoing capture and dis-arm the trigger. |
||||
|
||||
### FORCE_TRIGGER (24) |
||||
Manually set off the triggering condition. This is useful for testing the pre-trigger |
||||
configuration. |
||||
|
||||
### BLOCK_CAPTURE (25) |
||||
Start a manual block capture. This is similar to `FORCE_TRIGGER`, but includes no pre-trigger and the length is defined in the command. |
||||
|
||||
*Request:* |
||||
- u32 - number of samples to capture |
||||
|
||||
### STREAM_START (26) |
||||
Start a capture stream using the current sample rate and other settings. |
||||
|
||||
### STREAM_STOP (27) |
||||
Stop a stream. This is effectively equivalent to `ABORT`, but only allowed when |
||||
a stream is running. |
||||
|
||||
### SET_SMOOTHING_FACTOR (28) |
||||
Set the exponential averaging smoothing factor. |
||||
See the unit settings for the formula. |
||||
|
||||
*Request:* |
||||
- u16 - factor 0-1000, equivalent to 0.0-1.0 |
||||
|
||||
### SET_SAMPLE_RATE (29) |
||||
Set the sampling frequency. |
||||
|
||||
*Request:* |
||||
- u32 - frequency in Hz |
||||
|
||||
### ENABLE_CHANNELS (30) |
||||
Select chanbnels to enable. |
||||
|
||||
*Request:* |
||||
- u32 - bit-map of the enabled channels (bits numbered from LSB=0) |
||||
|
||||
### SET_SAMPLE_TIME (31) |
||||
Set sampling time. This is the time the ADC waits for the internal sampling capacitor |
||||
to charge before starting the SAR algorithm. Shorter times should in theory allow faster |
||||
sample rates, but since the main bottleneck here is the communicaton port, this doesn't |
||||
have much consequence and setting it too short only degrades performance with no |
||||
benefits. |
||||
|
||||
*Request:* |
||||
- u8 - sample time 0-7 (see the STM32F072 reference manual for details) |
||||
|
||||
## Events |
||||
|
||||
... |