<refentry id="{@id}">
|
|
<refnamediv>
|
|
<refname>Phpmodbus user's guide</refname>
|
|
<refpurpose>Phpmodbus How-to</refpurpose>
|
|
</refnamediv>
|
|
<refsynopsisdiv>
|
|
<author>
|
|
Jan Krakora
|
|
<authorblurb>
|
|
{@link mailto:jak.krakora@wago.com email}
|
|
</authorblurb>
|
|
</author>
|
|
</refsynopsisdiv>
|
|
{@toc}
|
|
<refsect1 id="{@id intro}">
|
|
<title>Introduction</title>
|
|
<para>
|
|
Phpmodbus is a PHP library for the Modbus protocol. The library implements
|
|
Modbus UDP master class with subset of the most used Modbus commands.
|
|
</para>
|
|
<para>
|
|
The library implements:
|
|
<itemizedlist>
|
|
<listitem><para>FC 3: read multiple registers</para></listitem>
|
|
<listitem><para>FC 16: write multiple registers</para></listitem>
|
|
<listitem><para>FC 23: read write registers</para></listitem>
|
|
</itemizedlist>
|
|
</para>
|
|
<para>
|
|
For more about Modbus protocol see [{@link http://www.modbus.org}] or
|
|
[{@link http://en.wikipedia.org/wiki/Modbus Wiki}]
|
|
</para>
|
|
<note>
|
|
Developed with support of <graphic fileref="wago_logo.png"/> {@link http://www.wago.com}.
|
|
</note>
|
|
</refsect1>
|
|
<refsect1 id="{@id intro}">
|
|
<title>Installation</title>
|
|
<para>
|
|
At the first, it is supposed an PHP solution has been already installed on
|
|
your server (LAMP, WAMP, MSS+CGI etc.).
|
|
</para>
|
|
<para>
|
|
Copy the Phpmodbus library to your PHP project folder.
|
|
</para>
|
|
<para>
|
|
Create a PHP script and assign the library using
|
|
<programlisting role="ini">
|
|
<![CDATA[ require_once dirname(__FILE__) . './Phpmodbus/ModbusMasterUdp.php'; ]]>
|
|
</programlisting>
|
|
</para>
|
|
<para>
|
|
To create the Modbus master object, that will communicate with a Modbus slave
|
|
at IP address 192.168.1.1, write
|
|
<programlisting role="ini">
|
|
<![CDATA[ $modbus = new ModbusMasterUdp("192.168.1.1"); ]]>
|
|
</programlisting>
|
|
</para>
|
|
<para>
|
|
To read 5 words (10 bytes) located at the memory beginning at address = 12288 of
|
|
the devide with Modbus ID=0 use
|
|
<programlisting role="ini">
|
|
<![CDATA[ $recData = $modbus->readMultipleRegisters(0, 12288, 5); ]]>
|
|
</programlisting>
|
|
</para>
|
|
<para>
|
|
For other examples see sections bellow.
|
|
</para>
|
|
</refsect1>
|
|
<refsect1 id="{@id examples}">
|
|
<title>Examples</title>
|
|
<para>
|
|
This section presents library features and examples
|
|
</para>
|
|
<refsect2 id="{@id example_fc3}">
|
|
<title>FC3 - read mutliple registers</title>
|
|
<para>
|
|
FC3 functionality example
|
|
</para>
|
|
<para>
|
|
{@example example_fc3.php}
|
|
</para>
|
|
</refsect2>
|
|
<refsect2 id="{@id example_fc16}">
|
|
<title>FC16 - write mutliple registers</title>
|
|
<para>
|
|
FC16 functionality example
|
|
</para>
|
|
<para>
|
|
{@example example_fc16.php}
|
|
</para>
|
|
</refsect2>
|
|
<refsect2 id="{@id example_fc23}">
|
|
<title>FC23 - read write registers</title>
|
|
<para>
|
|
FC23 functionality example
|
|
</para>
|
|
<para>
|
|
{@example example_fc23.php}
|
|
</para>
|
|
</refsect2>
|
|
<refsect2 id="{@id wago_example}">
|
|
<title>Dump of M-memory from WAGO 750-84x series coupler.</title>
|
|
<para>
|
|
Dump of M-memory from WAGO 750-84x series coupler.
|
|
</para>
|
|
<para>
|
|
{@example example_750841_Mmemory.php}
|
|
</para>
|
|
</refsect2>
|
|
<refsect2 id="{@id datatype}">
|
|
<title>Data conversion to PHP types.</title>
|
|
<para>
|
|
Conversion of the data bytes, received from Modbus, to a PHP type.
|
|
</para>
|
|
<para>
|
|
{@example example_datatype.php}
|
|
</para>
|
|
</refsect2>
|
|
</refsect1>
|
|
</refentry> |