You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
92 lines
2.3 KiB
92 lines
2.3 KiB
\section{Touch Sense Unit}
|
|
|
|
The touch sensing unit provides an access to the \gls{TSC} peripheral. Its function is explained in section \ref{sec:theory-touch}. The unit configures the \gls{TSC} and reads the output values of each enabled touch pad.
|
|
|
|
|
|
\subsection{Touch Sense Configuration}
|
|
|
|
\begin{inicode}
|
|
[TOUCH:touch@11]
|
|
# Pulse generator clock prescaller (1,2,4,...,128)
|
|
pg-clock-prediv=32
|
|
# Sense pad charging time (1-16)
|
|
charge-time=2
|
|
# Charge transfer time (1-16)
|
|
drain-time=2
|
|
# Measurement timeout (1-7)
|
|
sense-timeout=7
|
|
|
|
# Spread spectrum max deviation (0-128,0=off)
|
|
ss-deviation=0
|
|
# Spreading clock prescaller (1,2)
|
|
ss-clock-prediv=1
|
|
|
|
# Optimize for interlaced pads (individual sampling with others floating)
|
|
interlaced-pads=N
|
|
|
|
# Button mode debounce (ms) and release hysteresis (lsb)
|
|
btn-debounce=20
|
|
btn-hysteresis=10
|
|
|
|
# Each used group must have 1 sampling capacitor and 1-3 channels.
|
|
# Channels are numbered 1,2,3,4
|
|
|
|
# Group1 - 1:A0, 2:A1, 3:A2, 4:A3
|
|
g1_cap=
|
|
g1_ch=
|
|
# Group2 - 1:A4, 2:A5, 3:A6, 4:A7
|
|
g2_cap=
|
|
g2_ch=
|
|
# ...
|
|
\end{inicode}
|
|
|
|
|
|
\subsection{Touch Sense Events}
|
|
|
|
\begin{cmdlist}
|
|
0 & \cname{BUTTON\_CHANGE}
|
|
The binary state of some of the capacitive pads with button mode enabled changed.
|
|
& \begin{cmdpld}
|
|
\cfield{u32} binary state of all channels
|
|
\cfield{u32} changed / trigger-generating channels
|
|
\end{cmdpld} \\
|
|
\end{cmdlist}
|
|
|
|
%\newpage
|
|
\subsection{Touch Sense Commands}
|
|
|
|
\begin{cmdlist}
|
|
0 & \cname{READ}
|
|
Read the raw touch pad values (lower indicates higher capacitance). Values are ordered by group and channel.
|
|
& \begin{cmdreq}
|
|
\cfield{u16[]} raw values
|
|
\end{cmdreq} \\
|
|
|
|
1 & \cname{SET\_BIN\_THR}
|
|
Set the button mode thresholds for all channels. Value 0 disables the button mode for a channel.
|
|
& \begin{cmdreq}
|
|
\cfield{u16[]} thresholds
|
|
\end{cmdreq} \\
|
|
|
|
2 & \cname{DISABLE\_ALL\_REPORTS}
|
|
Set thresholds to 0, disabling the button mode for all pads.
|
|
& \\
|
|
|
|
3 & \cname{SET\_DEBOUNCE\_TIME}
|
|
Set the button mode debounce time (used for all pads with button mode enabled).
|
|
& \begin{cmdreq}
|
|
\cfield{u16} debounce time (ms)
|
|
\end{cmdreq} \\
|
|
|
|
4 & \cname{SET\_HYSTERESIS}
|
|
Set the button mode hysteresis.
|
|
& \begin{cmdreq}
|
|
\cfield{u16} hystheresis
|
|
\end{cmdreq} \\
|
|
|
|
\end{cmdlist}
|
|
|
|
|
|
|
|
|
|
|
|
|