\section{PWM Unit}
|
|
|
|
The \gls{PWM} unit uses a timer/counter to generate a \gls{PWM} signal. There are four outputs with a common frequency and phase, but independent duty cycles. Each channel can be individually enabled or disabled.
|
|
|
|
This unit is intended for applications like light dimming, heater regulation, or the control of H-bridges.
|
|
|
|
\todo[inline]{diagram, also show what is duty cycle}
|
|
|
|
\subsection{PWM Configuration}
|
|
|
|
\begin{inicode}
|
|
[PWMDIM:pwm@12]
|
|
# Default pulse frequency (Hz)
|
|
frequency=1000
|
|
# Pin mapping - 0=disabled
|
|
# Channel1 - 1:PA6, 2:PB4, 3:PC6
|
|
ch1_pin=1
|
|
# Channel2 - 1:PA7, 2:PB5, 3:PC7
|
|
ch2_pin=0
|
|
# Channel3 - 1:PB0, 2:PC8
|
|
ch3_pin=0
|
|
# Channel4 - 1:PB1, 2:PC9
|
|
ch4_pin=0
|
|
\end{inicode}
|
|
|
|
\subsection{PWM Commands}
|
|
|
|
\begin{cmdlist}
|
|
0 & \cname{SET\_FREQUENCY}
|
|
Set the PWM frequency
|
|
& \begin{cmdreq}
|
|
\cfield{u32} frequency in Hz
|
|
\end{cmdreq} \\
|
|
|
|
1 & \cname{SET\_DUTY}
|
|
Set the duty cycle of one or more channels
|
|
& \begin{cmdreq}
|
|
\item Repeat 1--4 times:
|
|
\begin{pldlist}
|
|
\cfield{u8} channel number 0--3
|
|
\cfield{u16} duty cycle 0--1000
|
|
\end{pldlist}
|
|
\end{cmdreq} \\
|
|
|
|
2 & \cname{STOP}
|
|
Stop the hardware timer. Outputs enter low level.
|
|
& \\
|
|
|
|
3 & \cname{START}
|
|
Start the hardware timer.
|
|
& \\
|
|
\end{cmdlist}
|
|
|
|
|
|
|
|
|