# Frequency / Pulse measurement
|
||||
|
||||
- Frequency measurement
|
||||
- Direct method (counting pulses in a time period)
|
||||
- Indirect method (measuring a single pulse)
|
||||
- PWM measurement - Indirect method also reports duty cycle
|
||||
- Single pulse measurement
|
||||
- Free-running pulse counter
|
||||
|
||||
### Direct vs Indirect method
|
||||
|
||||
The direct method works well for a wide range of frequencies, from Hz to tens of MHz. For
|
||||
very high frequencies, a prescaller can be enabled. This method has a best-case
|
||||
resolution of 1 Hz, which could be increased by extending the measurement time, which
|
||||
already needs to be long, usually 1 second or more for low frequencies.
|
||||
|
||||
The indirect method has a sub-Hz resolution and is much faster than the direct method for
|
||||
low frequencies. It can be used for signals up to tens of kHz, while the direct method
|
||||
can handle 20 MHz or more without issues.
|
||||
|
||||
*NOTE:* The accuracy of all measurements is dependent on the system clock speed.
|
||||
To measure the system clock using an external counter, you can output it on a pin using
|
||||
the MCO function configured in `SYSTEM.INI`.
|
||||
|
||||
### Burst vs Continuous
|
||||
|
||||
Both the direct and indirect methods can operate in a free-running or burst mode.
|
||||
|
||||
- Burst mode performs one or several measurements (with averaging if using the indirect method).
|
||||
- Free-running (continuous) mode performs periodic measurements without averaging.
|
||||
The advantage is that the last measurement is always immediately available for read-out, without having to wait for the emasurement.
|
||||
|
||||
## Commands
|
||||
|
||||
### STOP (0)
|
||||
|
||||
Stops all ongoing measurements.
|
||||
|
||||
### INDIRECT_CONT_START (1)
|
||||
|
||||
Start a free-running frequency / duty cycle measuring using the indirect method.
|
||||
|
||||
### INDIRECT_BURST_START (2)
|
||||
|
||||
Start a burst of indirect measurements.
|
||||
Waits for the next rising edge before starting the measurements.
|
||||
|
||||
*Request:*
|
||||
- u16 - number of pulses to average
|
||||
|
||||
*Response:*
|
||||
- u16 - core speed in MHz
|
||||
- u16 - number of pulses
|
||||
- u64 - sum of all periods (in core ticks)
|
||||
- u16 - sum of all on-times (positive interval of the pulse)
|
||||
|
||||
GEX avoids using float here to reduce code size and avoid floating
|
||||
point errors. To get the period, use `period_sec = periods / (mhz * 10e6 * count)`
|
||||
|
||||
Frequency is `freq = 1 / period`.
|
||||
|
||||
The average duty cycle is `duty = ontimes / periods`
|
||||
|
||||
### DIRECT_CONT_START (3)
|
||||
|
||||
Start repeated measurement using the direct method.
|
||||
|
||||
*Request:*
|
||||
- u16 - measurement time (ms)
|
||||
- 0 = no change
|
||||
- default 1000, configurable in the unit settings
|
||||
- u8 - prescaller (1,2,4,8)
|
||||
- 0 = no change
|
||||
- default 1, configurable in the unit settings
|
||||
|
||||
### DIRECT_BURST_START (4)
|
||||
|
||||
Start a single direct measurement (pulse counting) over
|
||||
a given time period. Longer periods can be used for higher precision
|
||||
using averaging.
|
||||
|
||||
*Request:*
|
||||
- u16 - measurement time (ms), often 1000 (=1s)
|
||||
- u8 - prescaller (1,2,4,8)
|
||||
- 0 = no change
|
||||
- default 1, configurable in the unit settings
|
||||
|
||||
*Response:*
|
||||
- u8 - prescaller (1,2,4,8)
|
||||
- u16 - measurement time (ms)
|
||||
- u32 - pulse count
|
||||
|
||||
Calculate the frequency by `freq = (1000 * count * presc) / time_ms`.
|
||||
|
||||
### FREECOUNT_START (5)
|
||||
|
||||
Clear and start the free-running pulse counter.
|
||||
|
||||
*Request:*
|
||||
- u8 - prescaller (1,2,4,8)
|
||||
- 0 = no change
|
||||
- default 1, configurable in the unit settings
|
||||
|
||||
### MEASURE_SINGLE_PULSE (6)
|
||||
|
||||
Measure a single pulse on the input. Waits for a rising edge.
|
||||
|
||||
*NOTE:* The result may be inaccurate if the input is High when starting the measurement.
|
||||
|
||||
*Response:*
|
||||
- u16 - core speed in MHz
|
||||
- u32 - pulse length (core ticks)
|
||||
|
||||
### FREECOUNT_CLEAR (7)
|
||||
|
||||
Clear the free-running counter while retrieving the current value.
|
||||
Normally no pulses should be missed, but please be aware that this
|
||||
operation is not atomic and glitches can occur at high frequencies.
|
||||
|
||||
*Response:*
|
||||
- u32 - last counter value
|
||||
|
||||
### INDIRECT_CONT_READ (10)
|
||||
|
||||
Read the latest result from the continuous indirect method measurement
|
||||
(measurement of individual pulses).
|
||||
|
||||
*Response:*
|
||||
- u16 - core speed in MHz
|
||||
- u32 - period (core ticks)
|
||||
- u32 - on-time (positive interval of the pulse)
|
||||
|
||||
Duty cycle is `duty = ontime / period`.
|
||||
Period `period_sec = period / (mhz * 10e6)`.
|
||||
Frequency `freq = 1 / period_sec`.
|
||||
|
||||
### DIRECT_CONT_READ (11)
|
||||
|
||||
Read the latest result from the continuous direct method measurement (pulse counting).
|
||||
|
||||
*Response:*
|
||||
- u8 - prescaller (1,2,4,8)
|
||||
- u16 - measurement time (ms)
|
||||
- u32 - pulse count
|
||||
|
||||
Frequency is `freq = (1000 * presc * count) / time_ms`.
|
||||
|
||||
### FREECOUNT_READ (12)
|
||||
|
||||
Read the current value of the free-running pulse counter.
|
||||
|
||||
*Response:*
|
||||
- u32 - counter value
|
||||
|
||||
### SET_POLARITY (20)
|
||||
|
||||
Set the measured pulse polarity.
|
||||
|
||||
*NOTE:* This is normally configured in the unit settings.
|
||||
Changes done through this method are temporary, not persisted to flash. The same
|
||||
applies to the other SET_* commands.
|
||||
|
||||
*Request:*
|
||||
- u8 - active level (0,1)
|
||||
|
||||
### SET_DIR_PRESC (21)
|
||||
|
||||
Set prescaller for the direct mode measurement.
|
||||
|
||||
*NOTE:* This does not take effect until the direct measurement is restarted. (TODO: fix?)
|
||||
|
||||
*Request:*
|
||||
- u8 - prescaller (1,2,4,8)
|
||||
|
||||
### SET_INPUT_FILTER (22)
|
||||
|
||||
Set input filtering (a hardware feature designed to ignore short glitches)
|
||||
|
||||
*Request:*
|
||||
- u8 - digital filtering factor (0-15, 0=off)
|
||||
|
||||
### SET_DIR_MSEC (23)
|
||||
|
||||
Set direct measurement period.
|
||||
|
||||
*NOTE:* This does not take effect until the direct measurement is restarted. (TODO: fix?)
|
||||
|
||||
*Request:*
|
||||
- u16 - period in milliseconds
|
||||
|
||||
### RESTORE_DEFAULTS (30)
|
||||
|
||||
Stop any measurement and restore all the run-time configurable settings to their default
|
||||
values (as configured in the unit settings).
|
||||