@ -1,18 +0,0 @@ |
||||
Out of abundance of caution, all code in this project should be considered available for private educational use only, |
||||
with no redistribution permitted in any form. Some files are available as MIT. |
||||
|
||||
Ask for clarification if needed: ondra@ondrovo.com |
||||
|
||||
|
||||
~~ Licensing for individual components ~~ |
||||
|
||||
Console |
||||
|
||||
proprietary (c) VZLU 2021, developed for VZLUSAT2 with CSP parts removed in this version. |
||||
Inspired by the esp32 console, including a modified 3rd party Linenoise library, and argtable3. |
||||
|
||||
BSEC |
||||
by Bosch, see the bme680 lib for details |
||||
|
||||
Web templating, telnet protocol, tcp socket server and the actual metering app |
||||
(c) Ondřej Hruška 2018-2022, these components are MIT. |
@ -1,55 +0,0 @@ |
||||
# ESP air quality sensor |
||||
|
||||
## Function |
||||
|
||||
- CO2 ppm |
||||
- air temperature |
||||
- relative humidity |
||||
- gas sensor VOC equivalent PPM |
||||
- gas sensor CO2 equivalent PPM |
||||
|
||||
### Data reading |
||||
|
||||
The module prints actual readings to the debug console. |
||||
|
||||
Data is accessible as JSON on a REST endpoint /sample, port 80 |
||||
|
||||
Example: |
||||
|
||||
``` |
||||
{"temp":22.80,"temp_r":22.86,"hum":45.33,"hum_r":45.15,"pres":98203.7,"gas_r":583406.1,"co2":620.00} |
||||
``` |
||||
|
||||
More data is included once BSEC2 (Bosch proprietary BME680 client / fusion library) finishes its calibration. See the `websrv.c` file for details. |
||||
|
||||
### Workarounds & reliability features |
||||
|
||||
The used CO2 sensor has buggy ABC algorithm that sometimes underflows. Further, I2C is very much broken on the sample used, so I use the Modbus interface instead. |
||||
Automatic restart and calibration restore is implemented for it. |
||||
|
||||
BSEC2 state persistence is implemented, but dubious if functional due to the millisecond timestamp logic. Air quality reports usually start coming after a couple hours of run time with varying ambient gas concentration. |
||||
|
||||
### Configuration |
||||
|
||||
Config via console on the serial port (115200-8-N-1), or telnet (port 22). |
||||
|
||||
WiFi can be configured and persisted, including static IP. WiFi scan is not implemented. |
||||
|
||||
## Hardware |
||||
|
||||
- BME680 in I2C mode |
||||
- SenseAir Sunrise (buggy early revision, will need updating for newer sensors) |
||||
|
||||
## Pinout |
||||
|
||||
- I2C_SDA0 16 - i2c for BME680 |
||||
- I2C_SCL0 17 |
||||
- I2C_SDA1 5 (senseair sunrise uart TX) |
||||
- I2C_SCL1 18 (senseair sunrise uart RX) |
||||
- CO2_NRDY 23 |
||||
- CO2_COMSEL 13 (high=uart) |
||||
- CO2_EN 15 sunrise restart pin, works like nReset |
||||
|
||||
## Licensing |
||||
|
||||